  1. -----------------------------------------------------------------------------
  2. 27th February 1993
  3. -----------------------------------------------------------------------------
  4. Support Group Application Note
  5. Number: 203
  6. Issue: 1
  7. Author:PFD
  8. -----------------------------------------------------------------------------
  9.  
  10. Master Series Configuration Guidelines
  11.  
  12. -----------------------------------------------------------------------------
  13. Applicable Hardware: BBC Master 128
  14.                      BBC Master ET
  15.                      BBC Master Compact
  16.  
  17. Related Application Notes:
  18.  
  19.  
  20. -----------------------------------------------------------------------------
  21. Copyright (C) Acorn Computers Limited 1992
  22.  
  23. Every effort has been made to ensure that the information in this leaflet is 
  24. true and correct at the time of printing. However, the products described in
  25. this leaflet are subject to continuous development and improvements and
  26. Acorn Computers Limited reserves the right to change its specifications at
  27. any time. Acorn Computers Limited cannot accept liability for any loss or
  28. damage arising from the use of any information or particulars in this
  29. leaflet. ACORN, ECONET and ARCHIMEDES are trademarks of Acorn Computers
  30. Limited.
  31. -----------------------------------------------------------------------------
  32. Support Group
  33. Acorn Computers Limited
  34. Acorn House
  35. Vision Park
  36. Histon
  37. Cambridge       CB4 4AE
  38. -----------------------------------------------------------------------------
  39.  
  40. After the Master series have had either their batteries or EEPROM replaced
  41. it will normally be necessary to perform some sort of re configuration. This
  42. document describes all the configuration options available and what the
  43. default settings are when the computer is supplied by Acorn.
  44.  
  45. *CONFIGURE Baud <0 - 8>
  46.  
  47. Description :   Sets the speed of the RS232 serial interface.
  48.                   
  49. Options :       0       9600
  50.                 1         75
  51.                 2        150
  52.                 3        300
  53.                 4       1200
  54.                 5       2400
  55.                 6       4800
  56.                 7       9600
  57.                 8      12000
  58.  
  59. Default :       4 (1200)
  60.  
  61.  
  62. *CONFIGURE Caps / NoCaps
  63.  
  64. Description :   Sets the keyboard caps lock.
  65.  
  66. Options :       Caps
  67.                 NoCaps
  68.  
  69. Default :       Caps
  70.  
  71. *CONFIGURE Data  <0 - 7>
  72.  
  73. Description : Specifies the data format used by the RS232 interface
  74. according to the specified value.
  75.  
  76. Options :
  77.  
  78.                 Value     Word Length   Parity  Stop Bits
  79.  
  80.                 0         7             even    2
  81.                 1         7             odd     2
  82.                 2         7             even    1
  83.                 3         7             odd     1
  84.                 4         8             none    2
  85.                 5         8             none    1
  86.                 6         8             even    1
  87.                 7         8             odd     1
  88.  
  89. Default :       4
  90.  
  91.  
  92. *CONFIGURE Delay <0 - 255>
  93.  
  94. Description :   Sets the keyboard auto-repeat delay to the specified number
  95. of hundredths of a second.
  96.  
  97. Default :       30
  98.  
  99. *CONFIGURE FDrive <0 - 7>
  100.  
  101. Description :   The computer is fitted with either a WD1770 or a WD1772 disc
  102. controller. FDrive defines the step time and, for ADFS, use of
  103. precompensation.
  104.  
  105. Options :
  106.                 Value    track to track      precompensation
  107.                          step time          (ADFS ADFS only)
  108.                  
  109.                         WD1770   WD1772
  110.  
  111.                 0 or 4   6ms      6ms        yes
  112.                 1 or 5   6ms      6ms        no
  113.                 2 or 6   30ms     3ms        yes
  114.                 3 or 7   30ms     3ms        no
  115.  
  116. Most drives require 6ms step time. Older drives may need the 30ms step time; modern drives may be able to operate at 3ms - consult your disc drive documentation.
  117.  
  118. Default :       0
  119.  
  120. *CONFIGURE File  <0 - 15)
  121.  
  122. Description :   Defines the default filing system by means of its ROM socket
  123. number.
  124.  
  125. Options :       Standard Master 128.
  126.  
  127.         ROM F TERMINAL 01
  128.         ROM E VIEW 04
  129.         ROM D Acorn ADFS 50
  130.         ROM C BASIC 04
  131.         ROM B Edit 01
  132.         ROM A ViewSheet 02
  133.         ROM 9 DFS 79
  134.         ROM 8 ?
  135.         ROM 7 ?
  136.         ROM 6 ?
  137.         ROM 5 ?
  138.         ROM 4 ?
  139.         ROM 3 ?
  140.         ROM 2 ?
  141.         ROM 1 ?
  142.         ROM 0 ?
  143.  
  144. The ROM numbers A - F are in HEX and correspond to Decimal 10 - 15.
  145.  
  146. Default :       ADFS = &D (14)
  147.                  
  148.  
  149.  
  150.  
  151. *CONFIGURE Hard / Floppy
  152.  
  153. Description : If the system has both floppy disc(s) and a Winchester disc
  154. connected, *CONFIGURE FLOPPY causes ADFS to initialise with drive 4 (floppy
  155. discs) selected. If the system has both floppy disc(s) and a Winchester disc
  156. connected, *CONFIGURE HARD causes ADFS to initialise with drive 0
  157. (Winchester) selected.
  158.  
  159. Default :       Floppy
  160.  
  161. *CONFIGURE Ignore <0 - 255>
  162.  
  163. Description : Defines the 'printer ignore character' (ie the character which
  164. is not to be directed to the printer), by means of its ASCII code. If the
  165. character code is omitted, all characters are sent to the printer when
  166. enabled.
  167.  
  168. Default :       0
  169.  
  170. *CONFIGURE InTube / ExTube
  171.  
  172. Description :   Causes either an internal or external TUBE to be selected in
  173. preference to the other.
  174.  
  175. Options :       InTube
  176.                 ExTube
  177.  
  178. Default :       InTube
  179.  
  180. *CONFIGURE Lang <0 -15>
  181.  
  182. Description :   Defines the default language by means of its ROM socket
  183. number.
  184.  
  185. Options :       Standard Master 128.
  186.  
  187.         ROM F TERMINAL 01
  188.         ROM E VIEW 04
  189.         ROM D Acorn ADFS 50
  190.         ROM C BASIC 04
  191.         ROM B Edit 01
  192.         ROM A ViewSheet 02
  193.         ROM 9 DFS 79
  194.         ROM 8 ?
  195.         ROM 7 ?
  196.         ROM 6 ?
  197.         ROM 5 ?
  198.         ROM 4 ?
  199.         ROM 3 ?
  200.         ROM 2 ?
  201.         ROM 1 ?
  202.         ROM 0 ?
  203.  
  204.  
  205.  
  206. The ROM numbers A - F are in HEX and correspond to Decimal 10 - 15.
  207.  
  208. Default :       BASIC = &C (13)
  209.  
  210. *CONFIGURE Quiet / Loud
  211.  
  212. Description :   Sets the BELL (CTRL G) Volume.
  213.  
  214. Options :       Quiet
  215.                 Loud
  216.  
  217. Default :       Quiet
  218.                  
  219.  
  220. *CONFIGURE Mode <0 - 7> or <128 - 135>
  221.  
  222. Description :   Defines the default MODE setting. MODEs <0 - 7> non Shadow
  223. screen modes. MODEs <128 - 135> Shadow screen modes.
  224.  
  225. Options : 
  226.  
  227.  Mode   Text Rows   Text Columns  Character   Graphic Pixels   Colours
  228.                                     Set
  229.  
  230. 0 (128)    32         80            ASCII       640 x 256          2        
  231. 1 (129)    32         40            ASCII       320 x 256          4  
  232. 2 (130)    32         20            ASCII       160 x 256         16
  233. 3 (131)    25         80            ASCII           -              2 
  234. 4 (132)    32         40            ASCII       320 X 256          2 
  235. 5 (133)    32         20            ASCII       160 X 256          4 
  236. 6 (134)    25         40            ASCII           -              2 
  237. 7 (135)    25         40           TELETEXT         -              -
  238.  
  239. DEFAULT :       7
  240.  
  241. *CONFIGURE BOOT / NOBOOT
  242.  
  243. Description : Set the Boot action of the machine on switch on. Boot tells
  244. the machine to attempt to run the !Boot file on a disc on switch on or CTRL
  245. BREAK. NOBOOT reverses the action of BOOT.
  246.  
  247. Options :        BOOT
  248.                  NOBOOT
  249.  
  250. Default :       NOBOOT
  251.  
  252. *CONFIGURE NODIR / DIR
  253.  
  254. Description :   Causes ADFS to initialise with a directory selected (either
  255. the root or, if ADFS has been since power on, the previously selected
  256. directory).
  257.  
  258.  
  259. Options :       DIR
  260.                 NODIR
  261.  
  262. Default :       NODIR
  263.  
  264. *CONFIGURE NOSCROLL / SCROLL
  265.  
  266. Description :   NOSCROLL enables the scroll protect option (ie prevents hard
  267. screen scrolling if a character is placed in the last character position of
  268. the bottom screen line, depending on the current mode.
  269.  
  270. Options :       SCROLL
  271.                 NOSCROLL
  272.  
  273. Default :       SCROLL
  274.  
  275. *CONFIGURE Print <0 - 4>
  276.  
  277. Description :   Defines the printer output port according to the value
  278. specified.
  279.  
  280. Options : 
  281.  
  282.  
  283.         0 Sink (No output printed)
  284.         1 Centronics (Parallel) port
  285.         2 RS232 (Serial) port
  286.         3 user printer driver
  287.         4 Econet (network printer) port
  288.  
  289. Default :       Sink (0)
  290.  
  291. *CONFIGURE Repeat <0 - 255>
  292.  
  293. Description :   Sets the keyboard repeat rate to the specified number of
  294. hundredths of a second.
  295.                      
  296. Default :       8
  297.  
  298. *CONFIGURE Tube
  299.  
  300. Description : Check for the presence of an internal or external co-processor
  301. and, if fitted, take the action specified by either the INTUBE or EXTUBE
  302. option.
  303.  
  304. Options :       TUBE
  305.                 NOTUBE
  306.  
  307. Default :       NOTUBE
  308.  
  309.  
  310. *CONFIGURE TV <0 - 255>,[<0 - 1>]
  311.  
  312. Description :   Alter the vertical screen alignment and set or reset the interlace option. The first parameter is interpreted as a signal byte ie. 1 means a movement of 1 line up and 255 (-1) means a movement of one line down. If parameter is 0 no adjustment is made to the vertical screen alignment. If the second parameter is 0 the screen interlace option is switched ON; if it is 1, the screen parameter is omitted the value zero is assumed.
  313.  
  314. Default :       0,1
  315.  
  316. The following options only apply to systems fitted with the ANFS (Advanced Network Filing System) ROM.
  317.  
  318. *CONFIGURE FS <x.xxx> or <Name>
  319.  
  320. Description :   Used to selected the default fileserver for logging onto.
  321.  
  322. Options :       FS Number  
  323.                 FS Name
  324.  
  325. eg. 
  326.  
  327. *CONFIGURE FS 0.254
  328.  
  329. or 
  330.  
  331. *CONFIGURE FS TecSupport
  332.  
  333. Default :       0.254
  334.  
  335. *CONFIGURE PS <x.xxx> or <Name>
  336.  
  337. Description :   Used to selected the default network printer server.
  338.  
  339. Options :       PS Number 
  340.                 PS Name 
  341.  
  342. *CONFIGURE FS 0.235
  343.  
  344. or 
  345.  
  346. *CONFIGURE FS Laser
  347.  
  348. Default :       0.235
  349.  
  350. *CONFIGURE SPACE / NOSPACE
  351.  
  352. Description :   On the BBC Master Series pages &B00 and &C00 are allocated
  353. as workspace to be used by the Econet filing system. On previous models
  354. these areas were used a buffers. Some existing software may try to use these
  355. areas and conflict with the operating system use of the space. The Econet
  356. system can be configured to claim other areas thus leaving pages &B00 and
  357. &C00 free for use with any application programs which are found to make
  358. inappropriate use of these areas.
  359.  
  360. Options : 
  361.  
  362.         SPACE - Pages claimed for transient commands. Effect on PAGE, OSHWM
  363. rises by &200.
  364.  
  365.         NOSPACE - PAGEs are not claimed and therefore the OSHWM is not
  366. increased.
  367.  
  368. Default :       NOSPACE
  369.  
  370. The following option only applies to BBC Master Compact and to BBC Master
  371. 128's that are fitted with the optional System ROM (3.50).
  372.  
  373. *CONFIGURE View Setup <xxx>
  374.  
  375. Description :   Define how View should start up.
  376.  
  377. Options : 
  378.  
  379.                 F - Format mode is on when View starts (an F will appear at
  380. the top left of the screen)
  381.                 J - Justify mode is on when View starts (a J will appear at
  382. the top left of the screen)
  383.                 I - Insert mode is on when View starts (an I will appear at
  384. the top left of the screen)
  385.  
  386. Default :       FJ
  387.  
  388. General Information
  389.  
  390. The *CONFIGURE commands must always be followed by a CTRL BREAK to
  391. initialise the settings in the machine.
  392.  
  393. It is possible to use Edit supplied with the BBC Master to created a
  394. standard file which contains all the *CONFIGURE options which could be used
  395. to re configure the machine in one go by using the *EXEC Command.
  396.  
  397. The Master Compact EEPROM has a limited life of 10,000 write operations. The
  398. chip is easily replaced when this limit is reached.
  399.  
  400. Acorn recommends that in the BBC Master the batteries are replaced every 12
  401. months.
  402.  
  403. If ROMs appear in the ROM table as being unplugged it is possible to re-
  404. insert then using the command *INSERT followed by the ROM Socket number eg.
  405.  
  406. *INSERT 13
  407.